Model:FST Series-LM35
Key Feature:1 μA/K Linear Current Output
MOQ(Standard):500 pcs
MOQ(Customized):TBD
Fucusens Solution

From LM35 Sensor IC to a Ready-to-Install Temperature Probe
A temperature sensor IC alone may not be ready for direct equipment installation. The complete sensor assembly also needs to match: Housing + Mechanical Structure + Cable + Connector + Mounting + Operating Environment.
Our Capability | What It Solves | Value to Your Business |
LM35 Precision Sensor | Temperature measurement requires a stable analog signal | Linear temperature-related voltage output |
Centigrade Scaling | Kelvin-based conversion adds processing steps | Easier Celsius temperature interpretation |
Analog Voltage Output | Digital communication is not required | Simple controller integration |
Custom Housing | Standard sensor package cannot be installed directly | Better mechanical compatibility |
Custom Probe Size | Limited installation space | Matches equipment structure |
Custom Cable | Standard cable does not fit application | Adapt insulation, gauge and length |
Accessories Available | Additional installation parts may be required | Easier system integration |
Typical Applications
Application | Typical Customer | Recommended Solution | Why This Configuration |
Heating Systems | Heating equipment and controller manufacturers | LM35 analog temperature probe | Linear voltage output supports simple temperature feedback |
Measuring Instruments | Instrument and measurement equipment manufacturers | Precision LM35 sensor assembly | Analog Celsius-scaled output supports measurement systems |
Washing Machines | Appliance manufacturers | Customized LM35 temperature probe | Housing and cable can be matched to appliance installation |
Over-Temperature Monitoring | Equipment and controller manufacturers | LM35 probe connected to analog control circuit | Temperature-related voltage can be used for monitoring logic |
General Equipment Temperature Measurement | OEM equipment manufacturers | Customized LM35 sensor probe | Probe, cable and mounting can be adapted to equipment |

Technical Specifications & Selection Guide
Parameter | Specification | Selection Notes |
Sensor | LM35 Series Precision Centigrade Temperature Sensor | Precision integrated-circuit temperature sensor |
Output | Analog Voltage Output | Voltage linearly proportional to Celsius temperature |
Scale Factor | 10 mV/°C | Direct Celsius-scaled analog output |
Operating Temperature Range | -55°C to +150°C* | Depends on the specific LM35 device / grade used |
Accuracy | Up to ±0.5°C at 25°C | Confirm accuracy over the actual operating range |
Supply Voltage | 4V to 30V | Match the controller / system supply |
Supply Current | Less than 60 μA typical | Low self-heating and low current consumption |
Non-Linearity | ±0.25°C typical | According to LM35 device characteristics |
Self-Heating | Approx. 0.08°C in still air | Depends on installation and thermal environment |
Probe Housing | Customizable | Material, size and configuration according to mounting |
Cable Insulation / Gauge / Length | Customizable | According to application and wiring requirements |
Product Structure & Selection Guide
Temperature Range — Confirm normal and maximum operating temperature.
Required Accuracy — Confirm the measurement accuracy required by the application.
Output Interface — Make sure the controller accepts the LM35 analog voltage signal.
Probe Structure & Size — Match the installation space and sensing position.
Housing Material — Select according to mechanical and environmental requirements.
Cable Insulation / Gauge / Length — Match temperature, wiring distance and equipment design.
Connector / Accessories — Match the existing controller or wiring harness.
3 Common Mistakes When Selecting a Pipe-Mounted NTC Sensor
1. Treating LM35 as a Digital Temperature Sensor
LM35 provides a linear analog voltage output, not a 1-Wire digital signal.
Better: Confirm that your controller accepts an analog temperature signal.
2. Focusing Only on the Sensor IC
A bare IC may still require mechanical protection, wiring and mounting.
Better: Evaluate the LM35 + Housing + Cable + Installation as one complete solution.
3. Ignoring Cable and Installation Requirements
Even when the sensor itself is suitable, the finished probe must match the equipment structure.
Better: Confirm housing + cable + connector + mounting before sample production.

From LM35 Sensor IC to a Ready-to-Install Temperature Probe
A temperature sensor IC alone may not be ready for direct equipment installation. The complete sensor assembly also needs to match: Housing + Mechanical Structure + Cable + Connector + Mounting + Operating Environment.
Our Capability | What It Solves | Value to Your Business |
LM35 Precision Sensor | Temperature measurement requires a stable analog signal | Linear temperature-related voltage output |
Centigrade Scaling | Kelvin-based conversion adds processing steps | Easier Celsius temperature interpretation |
Analog Voltage Output | Digital communication is not required | Simple controller integration |
Custom Housing | Standard sensor package cannot be installed directly | Better mechanical compatibility |
Custom Probe Size | Limited installation space | Matches equipment structure |
Custom Cable | Standard cable does not fit application | Adapt insulation, gauge and length |
Accessories Available | Additional installation parts may be required | Easier system integration |

Application | Typical Customer | Recommended Solution | Why This Configuration |
Heating Systems | Heating equipment and controller manufacturers | LM35 analog temperature probe | Linear voltage output supports simple temperature feedback |
Measuring Instruments | Instrument and measurement equipment manufacturers | Precision LM35 sensor assembly | Analog Celsius-scaled output supports measurement systems |
Washing Machines | Appliance manufacturers | Customized LM35 temperature probe | Housing and cable can be matched to appliance installation |
Over-Temperature Monitoring | Equipment and controller manufacturers | LM35 probe connected to analog control circuit | Temperature-related voltage can be used for monitoring logic |
General Equipment Temperature Measurement | OEM equipment manufacturers | Customized LM35 sensor probe | Probe, cable and mounting can be adapted to equipment |
Technical Data
Parameter | Specification | Selection Notes |
Sensor | LM35 Series Precision Centigrade Temperature Sensor | Precision integrated-circuit temperature sensor |
Output | Analog Voltage Output | Voltage linearly proportional to Celsius temperature |
Scale Factor | 10 mV/°C | Direct Celsius-scaled analog output |
Operating Temperature Range | -55°C to +150°C* | Depends on the specific LM35 device / grade used |
Accuracy | Up to ±0.5°C at 25°C | Confirm accuracy over the actual operating range |
Supply Voltage | 4V to 30V | Match the controller / system supply |
Supply Current | Less than 60 μA typical | Low self-heating and low current consumption |
Non-Linearity | ±0.25°C typical | According to LM35 device characteristics |
Self-Heating | Approx. 0.08°C in still air | Depends on installation and thermal environment |
Probe Housing | Customizable | Material, size and configuration according to mounting |
Cable Insulation / Gauge / Length | Customizable | According to application and wiring requirements |
Connector / Accessories | Available on request | According to equipment interface |
Sensor Construction & Selection Guide
Temperature Range — Confirm normal and maximum operating temperature.
Required Accuracy — Confirm the measurement accuracy required by the application.
Output Interface — Make sure the controller accepts the LM35 analog voltage signal.
Probe Structure & Size — Match the installation space and sensing position.
Housing Material — Select according to mechanical and environmental requirements.
Cable Insulation / Gauge / Length — Match temperature, wiring distance and equipment design.
Connector / Accessories — Match the existing controller or wiring harness.
3 Common Mistakes When Selecting a Clamp-Mount NTC Sensor
1. Treating LM35 as a Digital Temperature Sensor
LM35 provides a linear analog voltage output, not a 1-Wire digital signal.
Better: Confirm that your controller accepts an analog temperature signal.
2. Focusing Only on the Sensor IC
A bare IC may still require mechanical protection, wiring and mounting.
Better: Evaluate the LM35 + Housing + Cable + Installation as one complete solution.
3. Ignoring Cable and Installation Requirements
Even when the sensor itself is suitable, the finished probe must match the equipment structure.
Better: Confirm housing + cable + connector + mounting before sample production.
Sensor Performance Is Only One Part of a Reliable Temperature Probe
For a complete AD590 sensor assembly, quality control should cover both the sensing element and the mechanical/electrical assembly.
Incoming Material Inspection
· LM35 sensing components checked according to confirmed specification
· Probe housing materials inspected before production
· Cable insulation and conductor specifications verified
· Connectors and accessories checked according to project requirements
Process Control
· Sensor wiring controlled during assembly
· Sensing element positioned according to probe design
· Probe dimensions checked against approved drawing
· Cable gauge and length verified
· Connector or termination checked before final assembly
Finished Product Inspection
Test Item | Verification |
Sensor Function | Analog voltage output check |
Temperature Measurement | According to confirmed test requirement |
Probe Dimensions | According to approved drawing |
Cable Length / Gauge | According to specification |
Connector / Termination | According to confirmed interface |
Electrical Connection | Functional verification |
Appearance | Finished assembly inspection |
If You Are an Equipment Manufacturer / OEM
Common Problem | What It Means for Your Business |
The controller needs a simple analog temperature signal | Digital communication may add unnecessary system complexity |
Standard probe dimensions do not fit | Different equipment requires different housing and mounting structures |
Bare LM35 IC cannot be installed directly | Housing, cable and mechanical protection are still required |
Cable specifications do not match the equipment | Incorrect insulation, gauge or length requires modification |
The sensor output must integrate with existing analog circuitry | Electrical compatibility needs to be confirmed before production |
Different products need different probe structures | One standard assembly cannot cover every application |
If You Are a Distributor / Importer
Common Problem | What It Means for Your Business |
Customers need different housings | One standard probe cannot cover every project |
Customers require different cable specifications | Fixed wire configurations limit OEM opportunities |
Some customers need analog rather than digital sensors | A digital-only product range cannot cover all control systems |
Customers need ready-to-install assemblies | Bare sensor ICs require additional processing |
Technical matching takes too long | Sensor, housing, cable and interface must be confirmed together |
Need More Than an LM35 Sensor IC?
The LM35 provides the temperature-sensitive analog signal, but your equipment still needs the correct: Housing + Probe + Cable + Connector + Mounting Structure
Send us your drawing, existing sensor or application requirements.Get an LM35 Temperature Sensor Probe Configured for Your Equipment.
Sample Support
Standard Samples — Available according to current specifications and stock.
Customized Samples — Available after specification confirmation.
Housing Customization — Size and configuration according to mounting requirements.
Cable Customization — Insulation, gauge and length according to application.
Connector / Accessories — Available according to equipment interface.
Technical Support — Support for LM35 probe integration and application matching.
Sample Validation Before Mass Production
We recommend confirming: Temperature Measurement → Analog Output → Probe Structure → Housing → Cable → Connector → Installation. For customized assemblies, testing the sample under the actual installation condition is recommended before mass production.
Quality Assurance
Sensor Component — According to confirmed LM35 specification.
Probe Dimensions — According to approved drawing.
Cable — According to confirmed insulation, gauge and length.
Connector / Accessories — According to equipment interface.
Customized Products — Specifications confirmed before mass production.
Finished Assembly — Functional verification before shipment.
MOQ & Lead Time
Standard Product MOQ — Contact us for current MOQ.
Customized MOQ — Depends on housing, cable and accessory requirements.
Standard Lead Time — Contact us for current production schedule.
Customized Lead Time — Depends on assembly configuration.
Sample Lead Time — Confirmed after specification review.
Cooperation Process: Application Review → Temperature Range Confirmation → Output Interface Confirmation → Probe Design → Cable / Connector → Drawing Approval → Sample Testing → Pilot Order → Mass Production
Q1: What sensor is used?
The product uses an LM35 series precision integrated-circuit temperature sensor.
Q2: What type of output does LM35 provide?
It provides a linear analog voltage output proportional to Celsius temperature.
Q3: Is LM35 a digital sensor?
No. LM35 is an analog voltage-output temperature sensor.
Q4: What is the main advantage of Centigrade scaling?
The output is directly related to Celsius temperature, so the user does not need to subtract a large Kelvin offset to obtain °C measurement.
Q5: Can the probe housing be customized?
Yes. Housing material, size and configuration can be adjusted according to mounting requirements.
Q6: Can the cable be customized?
Yes. Cable insulation, gauge and length can be adapted according to project requirements.
Q7: Can accessories or connectors be supplied?
Yes. Other accessories are available on request.
Q8: Can you match our existing equipment?
Yes. Please provide your probe dimensions, mounting structure, cable and controller interface.
Q9: Can we send a drawing or existing sensor?
Yes. Drawings, photos and existing sensor information can be used for evaluation.
Q10: What information is required for a quotation?
Please provide: Application + Temperature Range + Required Accuracy + Probe Size + Housing + Cable + Connector / Accessories + Quantity




Expert for Thermistors Temperature Sensors Humidity Sensors Level Sensors ; Reliable but flexible custom products development
100+ Sensing Solutions Developed Annually for Different Applications
80+ Countries Customers Serviced